Measurements:
- ASTC, AIIC Ratings (FSTC, FIIC)
- Mechanical Devices and Systems
- Environmental Noise Survey
ASTC, AIIC Ratings (FSTC, FIIC)
- Condos
- Multi-Dwelling Buildings
- Shops
- Offices
- All Adjacent or Superimposed Premises
Noise spreads easily from one room to another when partitions or floor/ceiling assemblies are acoustically weak. ASTC (FITS) and AIIC (FIIC) acoustical measurements quantify the acoustic insulation performance of walls and floors with respect to airborne noise and impact noise.
The collected results are compared against the standards and recommendations to establish their compliance. The measures also make it possible to guide the design of the soundproofing means as well as to verify the results.
Noise Measurements of Building Mechanical Equipment and Systems
- Ventilation
- Air Conditioning
- Refrigeration
- Electric Generator
Sonar consultants en acoustique evaluates the sound levels of mechanical devices and systems to determine their compliance based on applicable standards (NC) and municipal and provincial regulations (dBA).
The complete measurements are used for calculations and for the design of noise control/reduction means.
Environmental Noise Surveys
- Urban Environments
- Routes
- Railways
- Industries
Governments and municipalities establish environmental noise requirements to prevent noise pollution from road and rail transport as well as industries.
Sonar consultants en acoustique carries out comprehensive on-site studies to assess environmental noise levels, among others for future residential construction and development projects.